• 简体中文
  • 한국어
  • Deutsch
Fluigent
  • Research
      • Flow EZ™ microfluidic flow controller
      • Microfluidic Instruments
        • Omi, automated organ-on-chip platform
        • Automated Sequential Injection System
        • Microfluidic Pressure Based Flow Controller
        • Microfluidic Sensors
        • Microfluidic Valves
        • Sample Reservoirs
        • Microfluidic Pressure Sources
        • Microfluidic Chips
        • Accessories
      • Software Solutions
        • Custom Software Development
        • Real-Time Control & Automation Software
      • Microfluidic Packs
        • Encapsulation Platform for FACS
        • Microfluidic Complex Emulsion Platform
        • Microfluidic Application Packs
        • Microfluidic Starter Packs
      • Research Applications
        • Microfluidics for Cell Analysis
        • Microfluidics for Organ-on-chip Cell culture
        • Microfluidics for Cell Biology
        • Microfluidics for Droplet Generation
      • Subscribe to the newsletter
  • Industrial
      • Microfluidic OEM Devices
        • Microfluidic OEM Components
        • Customizable OEM Flow Control Modules
      • Fully custom microfluidic device customization design microfluidic
      • Technologies
        • 5 reasons to choose OEM pressure controllers over OEM syringe pumps for microfluidic applications
        • Microfluidic recirculation system 
        • DFC, “Self-Learning” Microfluidic Flow Control Algorithm
        • Non-Intrusive Flow Sensing Technology
        • Compact All-In-One Microfluidic Micropump
      • Industrial Applications
        • Localization microscopy and flow control for multiplexing 
        • Contamination-free Liquid Handling System
        • Microfluidic Drug Discovery 
        • Flow Expertise for Cell Encapsulation and Single-Cell Analysis
        • Droplet Digital PCR (ddPCR)
      • Subscribe to the newsletter
  • Markets & Applications
    • Microfluidics in Life Science
    • Microfluidics for Pharmaceutical Applications
    • Microfluidics for Food testing & Agriculture
    • Microfluidics in Cosmetics
    • Microfluidics in Water analysis
  • Company
    • About us
    • Fluigent’s brand ambassadors
    • Team
    • News
    • Events
    • Fluigent Newsletter
    • Careers
  • Resources & Support
      • Expert Reviews: Basics of Microfluidics
        • Microfluidics tips
        • Industrial / OEM Microfluidic Expertise
        • What is microfluidics?
        • Advantages of pressure-based microfluidics
        • Elements of a microfluidic system
        • Concepts and physics of microfluidics
        • Droplet and particle generation in microfluidics
        • Microfluidic cell biology
        • Funded research program participation
      • FAQ
      • Videos
        • Expertise videos
        • Product presentation videos
        • Tutorial videos
      • Expertise
        • Videos
        • Paper highlights
        • Microfluidic Application Notes
        • Microfluidics case studies
        • Microfluidic Webinars
        • Interviews & Testimonials
        • Microfluidics White Papers
      • Documentation
        • CAD
        • Microfluidic Instruments Catalog
        • User manuals
        • Technical datasheets
        • Safety datasheet
        • Fluigent product icons & images
      • Microfluidic Calculators
        • Shear Stress Calculator
        • Pressure & Flow Rate Calculator
        • Droplet Size Calculator
      • Download software
        • OxyGEN
        • Software Development Kit
        • Discontinued software
      • Subscribe to the newsletter
  • Webshop
  • Contact us

Immunostaining Pack

O-MULTILABEL-PCK

    A ready-to-use package for sequential injection of multiple fluids for cell or tissue staining

    The Immunostaining Pack provides stable and automated delivery of up to 10 different fluids to a single cell culture chamber. 

    Ask for a quote
    perfusion package products
    Main benefits
    • USER FRIENDLY
      Easy

      Simple connections

    • Biocompatible
      Designed for cell biology

      Contamination-free, Sterile environment 

    • compact
      Compact

      Inject up to 10 different samples

    • Versatility

      Possibility to heat or agitate reservoir 

    Why use sequential injection for immunostaining?  

    Immunostaining is a multi-step technique for detecting the presence or localization of specific proteins, molecules, or cells within a biological or tissue sample.  

    Various reagents such as fixating agents or permeabilization buffers, are sequentially added to the samplewith incubation steps between each injection. 

    In the classic approach, all the reagents are added by manual pipetting: a time-consuming process that greatly increases the likelihood of errors occurings. Using microfluidic systems overcomes the limitations of conventional protocols. Automating the sequential steps by using our pressure-based flow controllers coupled with rapid low-volume valves not only saves time for the biologist, but also greatly improves the reproducibility of the assay. Switching from a bulk assay to a microfluidic format also allows for reduced reagent and sample volumes and shorter incubation times. 

    Our Immunostaining Pack combines all the equipment, software, and information you need to easily transfer your experiment from a bulk protocol to a microfluidic assay. 

    Features of the sequential injection pack  

    Complete system

    All the components you need for your experiment are included in the Immunostaining Pack.

    Versatility

    This package can be used for diverse applications, and with any microfluidic chip. 

    The reservoirs can be easily manipulated for heating, agitation, etc. 

    Stable flow rate & short switching time

    Fluigent’s products offer very stable delivery and short switching times to ensure optimal results for any immunostaining experiment. 

    Large sample volumes 

    Ten injection reservoirs allow for easy manipulation of large sample volumes,  and our pressure-based flow controller offers a wide range of pressure and flow rates. 

    Dedicated protocol for sequential injections 

    Up to 10 selected liquids can be delivered sequentially to a chip using the M-SWITCH. A 2-SWITCH can also be used to sort the samples at the outlet of the chip to a collection tube or to waste. 

    Build customized and time-based protocols to save time and reduce variability with our user-friendly OxyGEN software, designed for easy and complete protocol automation. 

    Related applications

    • Immunostaining
    • Microfluidics for Cell Analysis

      Discover
    • Microfluidics for Organ-on-chip Cell culture

      Discover
    • Microfluidics for Cell Biology

      Discover
    • Chip preparation : Chip coating, cell loading, cell incubation

    Main components of the Immunostaining Pack 

    • Flow EZ™ microfluidic flow controller

      Microfluidic flow controller

      Microfluidic flow controller

    • LINK Microfluidic Software control

      Microfluidic Software Control 

      Microfluidic Software control

    • Airtight metal tube caps for microfluidics

      P-CAP series

    • FLOW UNIT microfluidic flow sensor

      Bidirectional Microfluidic Flow Sensor

      Bidirectional Microfluidic Flow Sensor

    • MICROFLUIDIC SAMPLING VALVE

      Microfluidic Sampling Valve

      Microfluidic Sampling Valve

    • M-SWITCH™, Fluigent Microfluidic Bidirectional Valve

      M-SWITCH™ Microfluidic bidirectional valve 

      M-SWITCH™ Microfluidic bidirectional valve 

    • Real-Time Control & Automation Software

      Real-time control and Automation software

    setup Immunostaining Pack manifold hidden
    Figure 1: Complete setup for an immunostaining experiment.  

    Pack Specifications 

    PRODUCTS

    Our Immunostaining Pack includes the following components: 

    LineUp Flow EZ pressure controller (1000 mbar) (x1)
    LineUp LINK Module (software control) (x1)
    FLOW UNIT M (x1)
    2-SWITCH (x1)
    SWITCH EZ (x1)
    P-CAP series 15 mL (x12)
    M-SWITCH (x1)
    10 Position Pressure Manifold (x1)
    Immunostaining Pack setup
    Fig 2 : Complete Schematic of the Immunostaining Package
    Setup Immunostaining Package with manifold
    Fig 3 : Complete Setup of the Immunostaining Package

    FLUID HANDLING SYSTEM

    ProductPart number
    1*Flow EZLU-FEZ-1000
    1*2-SWITCH2SW002
    1*SWITCH EZELUSEZ
    1*LINK moduleLU-LNK-0002
    1*M-SWITCHESSMSW003

    RESERVOIRS

    ProductPart number
    12*15 mL Pcap with 15 mL Falcon tubeP-CAP15-HP
    1*10 Position Pressure ManifoldCTQ-MANI

    FLOW METERS

    ProductPart number
    1*Flow unit M FLU-M-D

    TUBING

    ProductPart number
    Tubing and connection Kit P-CAP 15mL
    FEP tubing with an ID of 500 microns
    CTQ-KIT-PC15
    1*Tubing and connection Kit 2-SWITCH CTQ-KIT-2SW2
    1*Tubing and connection Kit Flow UNIT MCTQ-KIT-LQ
    1*Tubing and connection Kit M-SWITCHCTQ-KIT-ESSMSW003

    OxyGEN

    Real-time control, automated protocol, data record and export
    ver. 2.2.0.0 or more recent

    See the offer


    Software Development Kit

    Custom software application
    ver. 22.2.0.0 or more recent

    See the offer


    “We have been using Fluigent’s M-SWITCH, amongst other accessories, including Flow EZ system, flow controllers,  for the past 5 years. We are pleased with its performance, especially the programmability and automation of fluid flow that relieves the user of the need to be present next to the experiments that run for several hours. We found the software interface to be simple to use and could count on the team’s assistance for friendly recommendations and support.”

    Sivashankar Krishnamoorthy – Luxembourg Institute of Science and Technology (LIST) 

    See more about M-SWITCH

    Aria: a fully integrated system  

    Run sequential perfusion and immunostaining experiments in an automated, intuitive, and completely integrated system with our ready-to-use Aria system. 

    The Aria is our automated solution for cellular perfusion or timed injection protocols, allowing for the automatic delivery of up to 10 different solutions into a chamber or microfluidic chip, according to user-defined protocols. 

    ARIA sequential injection
    Learn more about Aria

    Expertise & resources

    • Technical datasheets Immunostaining Package Datasheet Download
    • Microfluidic Webinars Automated fluid delivery for cell and tissue imaging Read more
    • Microfluidic Application Notes Development of a human gut-on-chip to assess the effect of shear stress on intestinal functions Read more
    • Expert Reviews: Basics of Microfluidics How to choose a microfluidic chip Read more
    • Microfluidics White Papers An exploration of Microfluidic technology and fluid handling  Read more
    • Technical datasheets M-SWITCH™ Datasheet Download
    • User manuals Easy Switch Solutions User Manual Download
    • Microfluidic Application Notes Capture and Labeling of Cancer Cells Using Aria Read more
    • Microfluidic Webinars Concepts of microfluidics Read more
    • Microfluidic Webinars Automate Cellular Studies with Aria Read more
    • Microfluidic Webinars Organ on a chip Towards the next generation of cell culture platforms Read more
    • Microfluidic Webinars LineUp Series, the new generation of microfluidic controllers Read more
    • Microfluidics case studies CEA/CNRS: A flow cell for nanoscopic imaging in liquid Read more
    • User manuals SWITCH EZ User Manual Download
    • Technical datasheets SWITCH EZ Datasheet Download
    • Expert Reviews: Basics of Microfluidics Extended capabilities of pressure driven flow for microfluidics applications Read more
    • Expert Reviews: Basics of Microfluidics What is a microfluidic chip? Read more
    • Expert Reviews: Basics of Microfluidics Microfluidic chips: key applications Read more
    • Technical datasheets Flow EZ™ Datasheet Download

    Related products

    • Automated sequential perfusion microfluidic

      Automated Sequential Injection System

      Automated Sequential Injection System

      See the offer
    • Flow EZ™ microfluidic flow controller

      Microfluidic flow controller

      Microfluidic flow controller

      See the offer
    • FLOW UNIT microfluidic flow sensor

      Bidirectional Microfluidic Flow Sensor

      Bidirectional Microfluidic Flow Sensor

      See the offer
    • Microfluidic Valve Controller

      Microfluidic valve controller

      See the offer
    • Fluigent L Switch

      Microfluidic Recirculation Valve

      Microfluidic Recirculation Valve

      See the offer
    • M-SWITCH™, Fluigent Microfluidic Bidirectional Valve

      M-SWITCH™ Microfluidic bidirectional valve 

      M-SWITCH™ Microfluidic bidirectional valve 

      See the offer
    • Cell perfusion pack

      Organ on Chip Perfusion Pack 

      Perfect organ-on-chip cell perfusion set

      See the offer

    Accessories

    • Microfluidic Low Pressure Generator

      Discover
    • bubble trap

      Bubble Trap

      Discover
    Logo fluigent green and blue

    67 avenue de Fontainebleau
    94 270 Le Kremlin-Bicêtre

    Research

    • Microfluidic Research Applications
    • Instruments
    • Software solutions
    • Packages

    Industrial

    • Products

    Resources

    • Microfluidic Application Notes
    • Microfluidics case studies
    • Expert Reviews: Basics of Microfluidics
    • Interviews & Testimonials
    • Microfluidic Webinars

    Support & tools

    • Documentation
    • Download software

    Company

    • About us
    • Team
    • Events
    • Newsletter
    • Careers

    Legal

    • Terms & Conditions of Sale
    • Legal Terms & Privacy Policy