• 简体中文
  • 한국어
  • Deutsch
Fluigent
  • Research
      • Flow EZ™ microfluidic flow controller
      • Microfluidic Research Equipment
      • Microfluidic Instruments
        • Omi, an Automated Organ-On-A-Chip Platform
        • Automated Perfusion System for Spatial Omics 
        • Microfluidic Pressure Based Flow Controller
        • Microfluidic Sensors
        • Microfluidic Valves
        • Pressure Control Reservoirs
        • Microfluidic Pressure Sources
        • Microfluidic Chips
        • Microfluidic Accessories
      • Software Solutions
        • Lab Integration Software
        • Real-Time Control & Lab Automation Software 
      • Microfluidic Packs
        • UV-crosslinked microcapsule production platform 
        • Encapsulation Platform for FACS
        • Microfluidic Complex Emulsion Production Platform
        • Microfluidic Application Packs
        • Microfluidic Starter Packs
      • Research Applications
        • Microfluidics for Cell Analysis
        • Microfluidics for Organ-on-chip Cell culture
        • Microfluidics for Droplet Generation
        • Microfluidics for Cell Biology
      • Subscribe to the newsletter
  • Industrial
      • Microfluidic OEM
      • Microfluidic OEM Devices
        • Microfluidic OEM Components
        • Customizable OEM Flow Control Modules
      • Fully Custom Microfluidic Device
      • Custom microfluidic device
      • Technologies
        • A Microfluidic Pressure Controller Comparison for Your Ultimate Fluid Control System
        • 5 reasons to choose OEM pressure controllers over OEM syringe pumps for microfluidic applications
        • Microfluidic recirculation system 
        • DFC, “Self-Learning” Microfluidic Flow Control Algorithm
        • Non-Intrusive Flow Sensing Technology
        • Compact All-In-One Microfluidic Micropump
        • Liquid Stirring Solutions
      • Industrial Applications
        • Combining Microfluidics and Spectroscopy
        • Valve Automation with the F-OEM for Microfluidic Applications
        • Localization microscopy and flow control for multiplexing 
        • Contamination-free Liquid Handling System
        • Microfluidic Drug Discovery 
        • Flow Expertise for Cell Encapsulation and Single-Cell Analysis
        • Droplet Digital PCR (ddPCR)
      • Subscribe to the newsletter
  • Markets & Applications
    • Microfluidics in Life Science
    • Microfluidics for Pharmaceutical Applications
    • Microfluidics for Food testing & Agriculture
    • Microfluidics in Cosmetics
    • Microfluidics in Water analysis
  • Company
    • About us
    • Fluigent’s Academic Partners
      • Scientific Partners
      • Fluigent’s Brand Ambassadors
      • Center Partners
    • Team
    • News
    • Events & Webinars
    • Fluigent Newsletter
    • Fluigent’s Distributors
    • Careers
  • Resources & Support
      • Expert Reviews: Basics of Microfluidics
        • General overview of microfluidics
        • Advantages of pressure-based microfluidics
        • Microfluidics tips
        • Droplet & Particle Generation
        • Microfluidic cell biology
        • Industrial / OEM Expertise
        • Funded research program
      • FAQ
      • Videos
        • Expertise videos
        • Product presentation videos
        • Tutorial videos
      • Expertise
        • Videos
        • Microfluidics Article Reviews
        • Microfluidic Application Notes
        • Microfluidics case studies
        • Interviews & Testimonials
        • Microfluidics White Papers
      • Documentation
        • CAD
        • Fluigent Catalog
        • Fluigent products manual
        • Fluigent Products Datasheets
        • Safety datasheet
        • Fluigent Media Kit product icons & images
      • Microfluidic Calculators
        • Shear Stress Calculator
        • Pressure & Flow Rate Calculator
        • Droplet Size Calculator
      • Download software
        • FEZ and Link Firmware Updater​
        • OxyGEN
        • Software Development Kit
        • Discontinued software
      • Subscribe to the newsletter
  • Webshop
  • Contact us
Home » Research » Microfluidic Instruments » Microfluidic Pressure Based Flow Controller » LineUp series » Microfluidic valve controller for flow redirection

Microfluidic valve controller for flow redirection

[ELUSEZ]

    SWITCH EZ

    The LineUp™ SWITCH EZ is a microfluidic valve controller that provides power and PC control for Fluigent’s microfluidic valves. The module has 6 ports and can be combined with other LineUp™ products for a complete and compact system for benchtop use. Connected valves can be controlled or programmed by using the local control directly on the device or by creating an automated protocol to automate valve actuation timing.

    Ask for a quoteSpecifications
    microfluidic valve controller
    Main benefits
    • USER FRIENDLY
      Intuitive

      Straight forward set up & use

    • compact
      Compact

      Uses minimum bench space

    • Smart

      Local & simultaneous control

    • adaptable
      Adaptable

      Control with or without a PC

    Features of the microfluidic valve control system

    Standalone configuration

    The SWITCH EZ can be used without a computer to control Fluigent’s microfluidic valves. Connect the valves to the dedicated ports and use the local control to actuate them. 

    Local control

    Control pressure or flow rate without a PC using the LineUp™ hardware interface. This allows users to quickly actuate connected valves and even order simultaneous requests. 

    Software and flow control

    Combine this microfluidic valve control system with any LineUp™ controller and a LINK to benefit from OxyGEN software. Control in real-time and automate valve actuation timing. 

    Related applications

    • Microfluidics for Droplet Generation

      Discover
    • Microfluidics for Organ-on-chip Cell culture

      Discover

    How to easily actuate or automate microfluidic valves

    Fluigent offers a wide range of microfluidic valves that are precisely and accurately matched to the experiment being performed. This gives users the possibility to use multiple valves for automatic liquid injection, work with very short switching time, and create a low internal volume with high chemical compatibility.  

    Our microfluidic valve controller allows users to control fluid sequences during an experiment, enabling automation of the process. The controller also has the ability to easily recreate processes that fit your specific needs, creating a complete valve automation. 

    The module has 6 ports and can be combined with other LineUp™ products to have a complete and compact system for benchtop use. Connected valves can be controlled or programmed by using the local control directly on the device or by creating a protocol in real-time to automate valve actuation timing. 

    The LineUp™ SWITCH EZ microfluidic valve controller can be used for: 

    • Perfusion: the rotational valve enables the sequential injection of up to 10 different liquids.  
    • Injections of a defined volume metered through a loop. 
    • Recirculation: using two t-connectors and two 2-switches, it is possible to flow alternatively from reservoir A to B and B to A by circulating through the chip in the same direction. This is useful for long cell culture experiments. 

    Part of our LineUp Series

    Pressure and vacuum control, flow rate control, microfluidic valve automation, and software control. Select and combine the modules you need from our range of LineUp™ products. Our devices have become the gold standard for microfluidic flow control over the years. 

    Focus on the microscope. No PC is required

    Instead of looking at the PC, users can keep their eyes on the microscope and adjust the control dial with one hand. In this stand-alone configuration, the microfluidic valve controller allows for pressure or flow rate control and volume dispense, making it ideal for benchtop use. 

    How does a microfluidic valve work?  

    A microfluidic valve is a device designed to control and manipulate the flow of fluids on a microscale level. It is an essential component in microfluidic systems. 

    Microfluidic valves enable the precise control of fluid flow by selectively opening or closing channels within the microfluidic device and redirecting flow. They can regulate the movement of fluids or direct fluids into specific pathways. The Fluigent’s valves are  actuated by a motor that drives a rotor – where the fluidic path is engraved – against a stator – hosting the fluidic ports, allowing for the flow redirection, and can be managed by the microfluidic valve control system. 

    By controlling the flow, microfluidic valves allow researchers and engineers to perform various analytical and biological processes, such as chemical reactions, cell studies, DNA analysis, and diagnostic assays. 

    Specifications

    COMPATIBILITY

    Maximum number of supported valvesUp to six 2-SWITCH
    Up to three M-SWITCH or L-SWITCH

    HARDWARE SPECIFICATIONS

    Dimensions91,9 x 71,8 x 131 mm
    Weight317 g (0.7 lbs)

    ELECTRONICAL SPECIFICATIONS

    Power consumption6 W
    Electrical consumption2A (peak)

    OxyGEN

    Control in real-time, protocol automation, data record and export
    ver. 2.2.0.0 or more recent

    See the offer


    Software Development Kit

    Custom software application
    ver. 22.2.0.0 or more recent

    See the offer

    set up microfluidic valve controller

    Expertise & resources

    • Product presentation videos MICROFLUIDIC VALVE AUTOMATION: How to make it easy [SWITCH EZ] – Fluigent Read more
    • Product presentation videos Microfluidic Valves : SMART CONTROL and AUTOMATION of your fluidic path – Fluigent Read more
    • Fluigent products manual SWITCH EZ User Manual Download
    • Fluigent Products Datasheets SWITCH EZ Datasheet Download

    Related products

    • MICROFLUIDIC SAMPLING VALVE 2 switch

      Microfluidic Sampling Valve

      2-SWITCH™ 3-port/2-way

      See the offer
    • M-SWITCH™, Fluigent Microfluidic Bidirectional Valve

      M-SWITCH™ Microfluidic bidirectional valve 

      M-SWITCH™ Microfluidic bidirectional valve 

      See the offer
    • Fluigent L Switch microfluidic recirculation AND injection valve

      Microfluidic Recirculation Valve

      L-SWITCH™ 6-port/2-position

      See the offer
    • Microfluidic Push Pull controller

      Microfluidic Push Pull controller

      Regulate negative and positive pressure

      See the offer

    Accessories

    • Airtight metal tube caps for microfluidics

      Discover
    • Pressurized fluid reservoirs

      Microfluidic Pressurized Fluid Reservoirs

      Discover
    • Pressure Reducer for Mixed Pressure Range Modules

      Discover
    • Microfluidic Low Pressure Generator

      Discover
    • bubble trap

      Bubble Trap

      Discover

    Kits

    • LineUp supply kit

      Buy online
    Logo fluigent green and blue

    67 avenue de Fontainebleau
    94 270 Le Kremlin-Bicêtre

    Research

    • Microfluidic Research Applications
    • Instruments
    • Software solutions
    • Packages

    Industrial

    • Products

    Resources

    • Microfluidic Application Notes
    • Microfluidics case studies
    • Expert Reviews: Basics of Microfluidics
    • Interviews & Testimonials

    Support & Tools

    • Documentation
    • Download software

    Company

    • About us
    • Team
    • Events & Webinars
    • Newsletter
    • Fluigent’s Distributors
    • Careers

    Legal

    • Terms & Conditions of Sale
    • Legal Terms & Privacy Policy