• 简体中文
  • 한국어
  • Deutsch
Fluigent
  • Research
      • Flow EZ™ microfluidic flow controller
      • Microfluidic Instruments
        • Omi, automated organ-on-chip platform
        • Automated Sequential Injection System
        • Microfluidic Pressure Based Flow Controller
        • Microfluidic Sensors
        • Microfluidic Valves
        • Sample Reservoirs
        • Microfluidic Pressure Sources
        • Microfluidic Chips
        • Accessories
      • Software Solutions
        • Custom Software Development
        • Real-Time Control & Automation Software
      • Microfluidic Packs
        • Encapsulation Platform for FACS
        • Microfluidic Complex Emulsion Platform
        • Microfluidic Application Packs
        • Microfluidic Starter Packs
      • Research Applications
        • Microfluidics for Cell Analysis
        • Microfluidics for Organ-on-chip Cell culture
        • Microfluidics for Cell Biology
        • Microfluidics for Droplet Generation
      • Subscribe to the newsletter
  • Industrial
      • Microfluidic OEM Devices
        • Microfluidic OEM Components
        • Customizable OEM Flow Control Modules
      • Fully custom microfluidic device customization design microfluidic
      • Technologies
        • 5 reasons to choose OEM pressure controllers over OEM syringe pumps for microfluidic applications
        • Microfluidic recirculation system 
        • DFC, “Self-Learning” Microfluidic Flow Control Algorithm
        • Non-Intrusive Flow Sensing Technology
        • Compact All-In-One Microfluidic Micropump
      • Industrial Applications
        • Localization microscopy and flow control for multiplexing 
        • Contamination-free Liquid Handling System
        • Microfluidic Drug Discovery 
        • Flow Expertise for Cell Encapsulation and Single-Cell Analysis
        • Droplet Digital PCR (ddPCR)
      • Subscribe to the newsletter
  • Markets & Applications
    • Microfluidics in Life Science
    • Microfluidics for Pharmaceutical Applications
    • Microfluidics for Food testing & Agriculture
    • Microfluidics in Cosmetics
    • Microfluidics in Water analysis
  • Company
    • About us
    • Fluigent’s brand ambassadors
    • Team
    • News
    • Events
    • Fluigent Newsletter
    • Careers
  • Resources & Support
      • Expert Reviews: Basics of Microfluidics
        • Microfluidics tips
        • Industrial / OEM Microfluidic Expertise
        • What is microfluidics?
        • Advantages of pressure-based microfluidics
        • Elements of a microfluidic system
        • Concepts and physics of microfluidics
        • Droplet and particle generation in microfluidics
        • Microfluidic cell biology
        • Funded research program participation
      • FAQ
      • Videos
        • Expertise videos
        • Product presentation videos
        • Tutorial videos
      • Expertise
        • Videos
        • Paper highlights
        • Microfluidic Application Notes
        • Microfluidics case studies
        • Microfluidic Webinars
        • Interviews & Testimonials
        • Microfluidics White Papers
      • Documentation
        • CAD
        • Microfluidic Instruments Catalog
        • User manuals
        • Technical datasheets
        • Safety datasheet
        • Fluigent product icons & images
      • Microfluidic Calculators
        • Shear Stress Calculator
        • Pressure & Flow Rate Calculator
        • Droplet Size Calculator
      • Download software
        • OxyGEN
        • Software Development Kit
        • Discontinued software
      • Subscribe to the newsletter
  • Webshop
  • Contact us

Pressure Reducer for Mixed Pressure Range Modules

[LU-ADP-0001]

    Adapt

    The Flow EZ™ Adapt module is a pressure reducer from the LineUp series. Placed between two LineUp Flow EZ™ or LineUp™ Push-Pull pressure-based controllers with different input requirements, it enables users to build a system with many different pressure channel ranges. It reduces the outgoing pressure supply from the module to its left and provides the required pressure supply to the module on its right.

    Ask for a quote
    Main benefits
    • Adaptable

      Enables mixed pressure range

    • USER FRIENDLY
      Intuitive

      Straight forward set up & use

    • compact
      Compact

      Uses minimum bench space

    Focus on the microscope. No PC is required

    Instead of looking at the PC, users can keep their eyes on the microscope, adjusting the control dial with one hand. In this stand-alone configuration, the device allows for pressure or flow rate control and volume dispense making it ideal for benchtop use.

    Features of the pressure regulator 

    From higher to lower pressure 

    The Adapt module is always placed with the higher-pressure modules to its left and the lower-pressure modules to its right. 

    Compact size 

    The pressure reducer is a compact module that fits perfectly into your pressure-based controller line. The space needed to integrate it is minimal. 

    Compatibility 

    The Adapt module can be combined with flow controllers of any pressure range (7 bar, 2 bar, 25 mbar…) 

    Why use a pressure reducer? 

    In the field of microfluidics, achieving stable flow rates is crucial for obtaining reproducible and reliable results. To facilitate this, Fluigent provides pressure-based flow controllers like the LineUp Flow EZ™ and LineUp™ Push-Pull, which provide the necessary control with a very short response time. These pressure controllers can be combined to create a complete set-up, with each controller providing different pressure ranges tailored to different aspects of microfluidic experimentation. 

    To streamline the process of using multiple LineUp Flow EZ or Push-Pull controllers, and to minimize the need for multiple pressure sources, the Adapt module can be used to create a unified LineUp system. This pressure regulator allows the pressure at the outlet of a Flow EZ to be adjusted before the next Flow EZ is supplied, making it an ideal solution for achieving seamless pressure and flow controls in microfluidics experiments. 

    Figure 1: Using an Adapt module in a LineUp system 
    Pressure Reducer for Mixed Pressure Range Modules
    Figure 2: Picture of the set–up, using Flow EZ (1000, 345 and 69mbar) and the pressure regulator module 

    Setting up a LineUp system with the Adapt module 

    The pressure reducer can be used with multiple pressure-based flow controllers if they are to be combined and do not cover the same pressure ranges. 
    To connect an Adapt module, the procedure is the same as for connecting two Flow EZ: simply place the two modules in series and plug them together using the plug & play feature. One important thing to know is that the LineUp modules must be arranged from left to right with decreasing pressure supply requirements. 
    The “Chain to Chain Kit” can be used if your setup requires more flexibility on the lab bench. 

    Specifications

    Each LineUp™ Flow EZ or Push-Pull requires a specific amount of supplied pressure. To build a single LineUp™ system with multiple pressure ranges, use the Adapt to reduce the pressure supply and meet your exact requirements. 

    INPUT PRESSURE REQUIREMENT

    150 mbarLU-FEZ-0025
    150 mbar LU-FEZ-0069
    1100 mbar LU-FEZ-0345
    1100 mbar LU-FEZ-1000
    2100 mbar LU-FEZ-2000
    7100 mbar LU-FEZ-7000
    -800 mbar LU-FEZ-N025
    -800 mbar LU-FEZ-N069
    -800 mbar LU-FEZ-N345
    -800 mbar LU-FEZ-N800
    1100 mar and/or -800 mbarELUPPU1000

    Expertise & resources

    • Microfluidic Webinars LineUp Series, the new generation of microfluidic controllers Read more
    • User manuals LineUp™ series User Manual Download

    Related products

    • Flow EZ™ microfluidic flow controller

      Microfluidic flow controller

      Microfluidic flow controller

      See the offer
    • Push-Pull, Vacuum Pressure-Based Controller

      Standalone Vacuum Pressure-Based Controller

      Standalone Vacuum Pressure-Based Controller

      See the offer
    • LINK Microfluidic Software control

      Microfluidic Software Control 

      Microfluidic Software control

      See the offer
    • Fluigent P SWITCH MICROFLUIDIC VALVE

      Pneumatic Valve Controller

      Pneumatic Valve Controller

      See the offer

    Accessories

    • Airtight metal tube caps for microfluidics

      Discover
    • Pressurized fluid reservoirs

      Microfluidic Pressurized Fluid Reservoirs

      Discover
    • Microfluidic Low Pressure Generator

      Discover
    • bubble trap

      Bubble Trap

      Discover
    Logo fluigent green and blue

    67 avenue de Fontainebleau
    94 270 Le Kremlin-Bicêtre

    Research

    • Microfluidic Research Applications
    • Instruments
    • Software solutions
    • Packages

    Industrial

    • Products

    Resources

    • Microfluidic Application Notes
    • Microfluidics case studies
    • Expert Reviews: Basics of Microfluidics
    • Interviews & Testimonials
    • Microfluidic Webinars

    Support & tools

    • Documentation
    • Download software

    Company

    • About us
    • Team
    • Events
    • Newsletter
    • Careers

    Legal

    • Terms & Conditions of Sale
    • Legal Terms & Privacy Policy