• 简体中文
  • 한국어
  • Deutsch
Fluigent
  • Research
      • Flow EZ™ microfluidic flow controller
      • Microfluidic Research Equipment
      • Microfluidic Instruments
        • Omi, an Automated Organ-On-A-Chip Platform
        • Automated Perfusion System for Spatial Omics 
        • Microfluidic Pressure Based Flow Controller
        • Microfluidic Sensors
        • Microfluidic Valves
        • Pressure Control Reservoirs
        • Microfluidic Pressure Sources
        • Microfluidic Chips
        • Microfluidic Accessories
      • Software Solutions
        • Lab Integration Software
        • Real-Time Control & Lab Automation Software 
      • Microfluidic Packs
        • UV-crosslinked microcapsule production platform 
        • Encapsulation Platform for FACS
        • Microfluidic Complex Emulsion Production Platform
        • Microfluidic Application Packs
        • Microfluidic Starter Packs
      • Research Applications
        • Microfluidics for Cell Analysis
        • Microfluidics for Organ-on-chip Cell culture
        • Microfluidics for Droplet Generation
        • Microfluidics for Cell Biology
      • Subscribe to the newsletter
  • Industrial
      • Microfluidic OEM
      • Microfluidic OEM Devices
        • Microfluidic OEM Components
        • Customizable OEM Flow Control Modules
      • Fully Custom Microfluidic Device
      • Custom microfluidic device
      • Technologies
        • A Microfluidic Pressure Controller Comparison for Your Ultimate Fluid Control System
        • 5 reasons to choose OEM pressure controllers over OEM syringe pumps for microfluidic applications
        • Microfluidic recirculation system 
        • DFC, “Self-Learning” Microfluidic Flow Control Algorithm
        • Non-Intrusive Flow Sensing Technology
        • Compact All-In-One Microfluidic Micropump
        • Liquid Stirring Solutions
      • Industrial Applications
        • Combining Microfluidics and Spectroscopy
        • Valve Automation with the F-OEM for Microfluidic Applications
        • Localization microscopy and flow control for multiplexing 
        • Contamination-free Liquid Handling System
        • Microfluidic Drug Discovery 
        • Flow Expertise for Cell Encapsulation and Single-Cell Analysis
        • Droplet Digital PCR (ddPCR)
      • Subscribe to the newsletter
  • Markets & Applications
    • Microfluidics in Life Science
    • Microfluidics for Pharmaceutical Applications
    • Microfluidics for Food testing & Agriculture
    • Microfluidics in Cosmetics
    • Microfluidics in Water analysis
  • Company
    • About us
    • Fluigent’s Academic Partners
      • Scientific Partners
      • Fluigent’s Brand Ambassadors
      • Center Partners
    • Team
    • News
    • Events & Webinars
    • Fluigent Newsletter
    • Fluigent’s Distributors
    • Careers
  • Resources & Support
      • Expert Reviews: Basics of Microfluidics
        • General overview of microfluidics
        • Advantages of pressure-based microfluidics
        • Microfluidics tips
        • Droplet & Particle Generation
        • Microfluidic cell biology
        • Industrial / OEM Expertise
        • Funded research program
      • FAQ
      • Videos
        • Expertise videos
        • Product presentation videos
        • Tutorial videos
      • Expertise
        • Videos
        • Microfluidics Article Reviews
        • Microfluidic Application Notes
        • Microfluidics case studies
        • Interviews & Testimonials
        • Microfluidics White Papers
      • Documentation
        • CAD
        • Fluigent Catalog
        • Fluigent products manual
        • Fluigent Products Datasheets
        • Safety datasheet
        • Fluigent Media Kit product icons & images
      • Microfluidic Calculators
        • Shear Stress Calculator
        • Pressure & Flow Rate Calculator
        • Droplet Size Calculator
      • Download software
        • FEZ and Link Firmware Updater​
        • OxyGEN
        • Software Development Kit
        • Discontinued software
      • Subscribe to the newsletter
  • Webshop
  • Contact us
Home » Research » Microfluidic Instruments » Microfluidic Pressure Sources » Compact Pressure Source

Compact Pressure Source 

[E-AC-RX1-2500]

    Fluigent RX

    The RX Compact Pressure Source is an air compressor designed to deliver high-quality air for microfluidic applications.

    The compact air compressor fits in small spaces while delivering pressurized air between 500 and 2,500 mbar to any Fluigent flow controller (all have a positive range up to 2 bar).

    Ask for a quote
    microfluidic pressure source
    Main benefits
    • compact
      Compact design

      educed dimensions - Optimized design fits in congested lab areas

    • USER FRIENDLY
      User-friendly

       standard connection setup

    • adaptable
      Adaptable

      Use with or without a PC

    Features of our Pressure Source

    Compact

    With reduced dimensions of 106 x 96.5 x 61.5 mm, this small microfluidic pressure generator will fit on any lab bench.

    2 positions for 2 applications

    A switch located at the back of the device allows users to choose between 2 configurations: the left side, which delivers 1,300 mbar and enables the pressurization of 1 or 2 Flow -Ez 1 bars, and the right side, which delivers 2,400 mbar, and can be used to pressurize Flow Ez 2 bars.

    Filtered and dried air

    The compact pressure source reduces the pressurized air’s humidity to ensure there is no condensation. In addition, a built-in air filter prevents dust from entering the microfluidic system.

    Related applications

    • Microfluidics for Droplet Generation

      Discover
    • Microfluidics for Organ-on-chip Cell culture

      Discover
    • Microfluidics for Cell Biology

      Discover

    Combine with a Flow-Ez to ensure pulse-free flow

    The Fluigent RX compact air compressor can be easily connected to a Flow- Ez 1 bar or 2 bar to ensure a highly stable injection of fluids.

    Flow controller stability

    Specifications

    PNEUMATIC SPECIFICATIONS

    Minimum pressure500 mbar
    Maximum pressure2500 mbar
    Free flow (flow rate at 0 mbar output)0,8 L/min
    Flow rate at 2000 mbar5,6 L/min

    HARDWARE SPECIFICATIONS

    Dimensions (L*W*H)106 x 96,5 x 61,5 mm
    Weight823 g

    ELECTRONICAL SPECIFICATIONS

    Power voltage24 V
    Maximum current800 mA
    Maximum power consumption19 W

    Flow EZ

    Flow EZ™ microfluidic flow controller

    Flow EZ:

    • Up to 2 Flow EZ 1 bar
    • 1 Flow EZ 2 bar

    Expertise & ressources

    • Fluigent Products Datasheets RX Technical Specifications Download
    • Fluigent Products Datasheets RX Pressure Source Datasheet Download
    • Expert Reviews: Basics of Microfluidics Extended Capabilities of Pressure Driven Flow for Microfluidic Applications Read more
    Logo fluigent green and blue

    67 avenue de Fontainebleau
    94 270 Le Kremlin-Bicêtre

    Research

    • Microfluidic Research Applications
    • Instruments
    • Software solutions
    • Packages

    Industrial

    • Products

    Resources

    • Microfluidic Application Notes
    • Microfluidics case studies
    • Expert Reviews: Basics of Microfluidics
    • Interviews & Testimonials

    Support & Tools

    • Documentation
    • Download software

    Company

    • About us
    • Team
    • Events & Webinars
    • Newsletter
    • Fluigent’s Distributors
    • Careers

    Legal

    • Terms & Conditions of Sale
    • Legal Terms & Privacy Policy